APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 12009 Issued:2022-07-04
Revised:New
Style 12009 Single-conductor cable employing a non-extruded covering as the outermost layer.

Rating80 deg C, 60 Vac, Horizontal flame.
Conductor50 AWG - 10 AWG, solid or stranded.
InsulationExtruded PFA, 1.1 mils minimum average thickness, 1.0 mil minimum thickness at any point.
ShieldOptional.
CoveringNon-extruded, non-separable two layers. Inner layer - Spirally wrapped one metal-faced PET tape. Outer layer - Spirally wrapped one PET tape with adhesive. 0.6 mil total minimum average thickness, 0.4 mil total minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024