APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 12013 Issued:2022-08-26
Revised:2022-09-19
Style 12013 Single Conductor with Extruded Insulation

Rating80 deg C, 300 Vac, no flame.
Conductor30 AWG - 500 kcmil, solid or stranded.
InsulationExtruded PP
Conductor sizeAverage thicknessMinimum thickness at any point
30-16 AWG9 mils7 mils
14-10 AWG12 mils10 mils
9-8 AWG20 mils18 mils
7- 2 AWG30 mils27 mils
1-4/0 AWG40 mils36 mils
250-500 kcmil50 mils46 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Cables.

UL and the UL Logo are trademarks of UL LLC © 2024