| Rating | 90 deg C,125 Vac Horizontal flame. |
|
| Conductor | 50 AWG min., solid or stranded. |
|
| Insulation | Extruded FEP 2 mils minimum average thickness, 1 mil thickness at any point |
|
| Shield | Optional |
|
| Covering | Spirally wrapped PET film with polyester adhesive, 0.2 mils minimum average total thickness of the tape layers, 0.1 mil minimum total thickness of the tape layers at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring. |
|