APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 12083 Issued:2023-11-28
Revised:2023-12-04
Style 12083 Single Conductor with Extruded Insulation

Rating200 deg C, -40 deg C, 250 Vac, Horizontal Flame.
Conductor50 AWG - 19 AWG, Stranded Metal Coated.
InsulationExtruded PTFE - 6 mils minimum average thickness, 5 mils minimum at any point. See Facing page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024