APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 12100 Issued:2024-05-08
Revised:2024-06-12
Style 12100 Single conductor with extruced insulation

Rating105 deg C,30 Vac, Horizontal Flame, VW-1 flame.
Conductor32 AWG - 28 AWG, solid or stranded.
InsulationExtruded Solid FEP which consists of two concentric tubes with integral bridges to maintain air gap between tubes, overall thickness 4.0 mils min average and 3.0 mils min at any point, outer tube thickness 1.06 mils min at any point, inner tube thickness 0.65 mils min at any point and inter bridge thickness 0.74 mils min at any point.
StandardAppliance Wiring Material UL 758.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.