APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 12114 Issued:2024-08-08
Revised:2024-12-11
Style 12114 Single conductor cable using extruded non-integral jacket.

Rating150 deg C, 30000 Vdc, Cable Flame
Conductor26-16 AWG Stranded. See Facing page for details.
Semi-conductive polymeric layersExtruded PFA. See Facing page for details.
AssemblySingle conductor employing PFA semi-conductive layers, insulation, optional inner shield, optional inner covering, required outer shield, required outer covering and overall jacket all as described below.
InsulationExtruded PFA - 71 mils minimum average thickness, 64 mils minimum thickness at any point.
Inner ShieldOptional - Metal braided shield.
Inner CoveringOptional - Extruded or non-extruded foamed PTFE.
Outer ShieldMetal braided shield.
Outer CoveringExtruded or non-extruded foamed PTFE.
JacketExtruded PFA -
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0-0.350 inch12 mils9 mils
0.351-0.500 inch13 mils10 mils
0.501-0.700 inch15 mils12 mils
0.701-1.500 inch20 mils16 mils
1.500-2.500 inch30 mils24 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2025