Style 12115 Single conductor cable using non-integral extruded jacket.

Rating90 deg C, 600 Vac, Horizontal Flame.
Conductor40 AWG min., solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
ShieldOptional.
CoveringOptional.
BraidOptional.
JacketExtruded TPU
Diameter of assemply under jacketMinimum average thicknessMinimum thickness at any poiny
0.700 inch or less45 mils36 mils
0.701-1.000 inch60 mils48 mils
1.001-1.500 inch80 mils64 mils
1.501-2.500 inches110 mils88 mils
2.501 dia and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial - External Wiring with Horizontal Flame Rating.

UL and the UL Logo are trademarks of UL LLC © 2025