APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 12128 Issued:2024-11-07
Revised:2024-11-12
Style 12128 Single Conductor with Extruded Insulation

Rating90 deg C, 1000 Vac
Conductor32 AWG - 2000 kcmil, solid or stranded.
InsulationExtruded PP
Conductor SizeMinimum average thickness (mils)Minimum thickness at any point (mils)
32-10 AWG1614
9-6 AWG2219
5-2 AWG2825
1-4/03330
250-500 kcmil4540
501-1000 kcmil6054
1001-2000 kcmil8072
See Facing Page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Cables.