APPLIANCE WIRING MATERIAL
Subj.758
Section
1
Page
1216
Issued:
1960-04-06
Revised:
2011-07-28
Style
1216
Insulated Resistance Wire.
Rating
90 deg C, 250 Vac, Horizontal flame.
Conductor
Nickel-silver, nickel alloy, nickel chrome, copper alloy, or copper. Size varies dependent upon wattage demand.
Insulation
PVC, 30 mils min average, 27 mils minimum at any point.
Standard
Appliance Wiring Material UL 758.
Marking
General. The conductor alloy designation shall be included. Ohms per foot rating at 68 deg F (optional marking).
Use
"Thermoplastic Insulated Resistance Wire for Heating Cable Units where exposed to temperatures not exceeding 90 deg C." The conductor alloy designation shall be included. Ohms per foot rating at 68 deg F (optional marking).
UL and the UL Logo are trademarks of UL LLC © 2025