Rating | 75 deg C, 125 Vac, Horizontal flame. |
|
Conductor | 34 AWG minimum, wound spirally for a minimum of 35 turns per inch on a Polyester, Nylon (polyamide), Fiberglass, Cotton or Rayon yarn core. The diameter over the conductor and core shall be approximately 32 Mils. |
|
Insulation | Extruded PVC, 20 mils min average, 18 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | In Electrically Heated Blankets where exposed to temperatures not exceeding 75 deg C. |
|