APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1222 Issued:1996-09-13
Revised:2012-03-22
Style 1222 Single or multiple conductor with extruded insulation

Rating75 deg C, 125 Vac, Horizontal flame.
ConductorA copper alloy or hard drawn copper conductor 6.3 Mils nominal (5.9 Mils minimum) diameter shall be wound spirally for a minimum of 30 turns per inch on a Polyester, Nylon, Fiberglass, Cotton or Rayon yarn core. The diameter over the conductor and core shall be approximately 32 Mils. .
InsulationExtruded PVC, 20 mils min average, 18 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn Electrically Heated Blankets where exposed to temperatures not exceeding 75 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024