Rating | 60 deg C, 230 Vac, FT2 flame. |
|
Conductor | 14 AWG - 12 AWG solid or stranded, tinned or bare copper. |
|
Insulation | Nominal 30 mil wall of Thermoplastic (PVC) Compound suitable for use on Type TW wire. The insulation shall be red in color to indicate 230 volts rating.
Nominal 30 mil wall of Thermoplastic (PVC) Compound suitable for use on Type TW wire. The insulation shall be red in color to indicate 230 volts rating.
|
|
Covering | Extruded Nylon, 3 mils minimum thickenss at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Only as factory assembled Non-Heating Leads on Radiant Heating Cable units for use in concrete driveway, walk, etc. |
|