APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1234 Issued:1960-12-19
Revised:2011-08-16
Style 1234 Single conductor with extruded insulation.

Rating80 deg C, 600 Vac, Horizontal flame, Optional-Oil Resistant 60 deg C or 80 deg C.
Conductor8 AWG solid or stranded round.
InsulationPVC, 60 mils min average, 54 mils minimum at any point.
CoveringExtruded nylon in 2-mil minimum thickness or lacquered braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.