APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1235 Issued:1959-05-01
Revised:2014-02-25
Style 1235 Single conductor with extruded insulation

Rating105 deg C, 600 Vac, Horizontal flame. Optional - 60 deg C or 80 deg C Oil.
Conductor18 AWG - 8 AWG, solid or stranded.
InsulationExtruded PVC, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024