APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1242 Issued:1960-12-19
Revised:2012-01-11
Style 1242 Single Conductor with extruded insulation

Rating105 deg C, 300 Vac, Horizontal flame.
ConductorMinimum 0.0025 inch diameter resistance wire wound for a minimum 20 turns per inch on a Polyester yarn or Fiberglass yarn core .
InsulationExtruded PVC, 62 mils minimum average thickness.
CoveringExtruded Nylon (Polyamide), 2 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerators where exposed to temperatures not exceeding 105 deg C and where not subjected to flexing or motion.