APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1244 Issued:1960-12-19
Revised:2012-05-18
Style 1244 Single-conductor cable using extruded covering

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorResistance wire, solid or stranded, employing 26 AWG or larger wire.
InsulationExtruded PVC, 62 mils minimum average thickness.
CoveringExtruded Nylon, 2 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.