APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1250 Issued:1960-12-19
Revised:2011-10-19
Style 1250 Single conductor with extruded insulation.

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorResistance wire, 15 AWG minimum, wound for a minimum of 20 turns per inch on a Rayon, Cotton, Polyester, Fiberglass or Nylon (polyamide) yarn core.
InsulationExtruded PVC, 60 mils min average, 54 mils minimum at any point.
CoveringExtruded nylon (polyamide), 2 mils minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Refrigeration Equipment to prevent condensation of moisture on the outside of the freezer cabinet and where exposed to temperatures not exceeding 80 deg C.