APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1262 Issued:1960-12-19
Revised:2008-05-27
Style 1262 Single Conductor with Extruded Insulation.

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorMimimum 0.0015 inch diameter resistance wire wound for a minimum of 20 turns per inch on a Rayon, Cotton, Polyester, Fiberglass or Nylon yarn core.
InsulationPVC, 45 mils minimum average, 40 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Refrigeration Equipment to prevent condensation of moisture on the outside of the freezer cabinet.