APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1267 Issued:1961-02-24
Revised:2012-04-26
Style 1267 Sigle conductor with extruded insulation.

Rating75 deg C, 125 Vac, Horizontal flame.
ConductorA copper alloy heater wire shall be flattened and wrapped spirally for minimum of 38 turns per inch on a glass yarn core. The core and conductor are then insulated with two extruded walls of nylon avg. thickness of 4 mils. Over the nylon a copper alloy wire, flattened, shall be wrapped spirally for a minimum of 27 turns per inch.
InsulationExtruded PVC, 20 mils minimum average thikness, 18 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn General Electric Co. Electrically Heated Blankets where exposed to temperatures not exceeding 75 deg C, and where the suitability of the combination has been determined by Underwriters Laboratories, Inc.