APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1274 Issued:1961-05-10
Revised:2012-04-17
Style 1274 Insulated Shielded and jacketed wire.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationExtruded PE, 25 mils min average, 22 mils minimum at any point.
ShieldMetal serve, braid, or equivalent, conductive thermoplastic with drain wire, or aluminum- faced polyester with drain wire. Uninsulated drain wire optional where not specified.
JacketExtruded PVC, 31 mils min average, 23 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less.
UsePhonograph Pick-Up and Volume Control; or as Internal Wiring of Appliances at temperatures not exceeding 60C. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less.

UL and the UL Logo are trademarks of UL LLC © 2024