APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1281 Issued:1961-09-14
Revised:2011-09-01
Style 1281 Single-conductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldA conductive thermoplastic material 7 mils minimum thickness, in conjuction with a 20 AWG or 22 AWG, stranded or solid, tinned or bare copper bonding conductor. The shield may also be a wrap of aluminum faced polyester tape with a parallel uninsulated drain wire.
JacketExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in electronic equipment.