APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1282 Issued:1961-10-19
Revised:2011-08-16
Style 1282 Single conductor with extruded insulation using non integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded.
InsulationExtruded PE, 25 mils min average, 22 mils minimum at any point.
ShieldNo. 36-30 AWG, tinned or untinned copper strands applied as a wrap or braid, or a wrap of aluminium faced polyester tape with a parallel, uninsulated drain wire.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring Only.

UL and the UL Logo are trademarks of UL LLC © 2024