APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1285 Issued:1961-12-19
Revised:2011-08-11
Style 1285 Single Conductor with Extruded Insulation

Rating105 deg C, 125 Vac, Horizontal flame.
ConductorCopper, nickel-alloy or stainless steel conductor, 35-31 AWG, wound 10 turns per inch min, 70 turns per inch max on a core of Polyester, Acrylic, Fiberglass or Rayon. Core may be coated with Silicone Rubber.
InsulationPVC, 20 mils min average, 18 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn electrically heated pads, and where the acceptability of the combination has been determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024