APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1288 Issued:1962-01-24
Revised:2012-04-27
Style 1288 Insulated Shielded and Jacketed Wire.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round.
InsulationExtruded PE, 47 mils min average, 43 mils minimum at any point.
BraidOptional. Lacquered fibrous braid.
ShieldMetal serve, braid, or equivalent, conductive thermoplastic with drain wire, or aluminum-faced Polyster with drain wire. Uninsulated drain wire optional where not specified.
JacketExtruded PVC, 25 mils min average, 18 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-up and Volume Control; or as Internal Wiring of Appliances at temperatures not exceeding 80 deg C. When used, "Conductive PVC Shield" required in contrasting color at intervals of two feet or less.

UL and the UL Logo are trademarks of UL LLC © 2024