APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1289 Issued:1962-02-02
Revised:2011-09-09
Style 1289 Insulated Wire.

Rating60 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationPE, 30 mils min average, 27 mils minimum at any point.
ShieldA black colored conductive thermoplastic material 7 mil nominal, 6 mils minimum wall, in conjunction with a 26, 24, or 22 AWG stranded or solid, tinned or bare copper bonding conductor.
JacketPVC, 30 mils min average, 24 mils minimum at any point; The color of the jacket shall be other than black.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or Internal Wiring of Appliance where temperature does not exceed 60 deg C.
 
UL and the UL Logo are trademarks of UL LLC © 2024