APPLIANCE WIRING MATERIAL
Subj.758
Section
1
Page
1289
Issued:
1962-02-02
Revised:
2011-09-09
Style
1289
Insulated Wire.
Rating
60 deg C, 600 Vac, Horizontal flame.
Conductor
26 AWG - 16 AWG solid or stranded round, tinned or bare copper.
Insulation
PE, 30 mils min average, 27 mils minimum at any point.
Shield
A black colored conductive thermoplastic material 7 mil nominal, 6 mils minimum wall, in conjunction with a 26, 24, or 22 AWG stranded or solid, tinned or bare copper bonding conductor.
Jacket
PVC, 30 mils min average, 24 mils minimum at any point; The color of the jacket shall be other than black.
Standard
Appliance Wiring Material UL 758.
Marking
General.
Use
Phonograph Pick-Up and Volume Control; or Internal Wiring of Appliance where temperature does not exceed 60 deg C.