APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1296 Issued:1962-04-27
Revised:2012-04-26
Style 1296 Single Conductor with Extruded Insulation and Non-Integral Jacket

Rating105 deg C, 300 Vac (Insulation), 600 Vac (Jacket), Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded round.
InsulationExtruded PVC, 15 mils minimum average thickness, 14 mils minimum thickness at any point.
Shield36-30 AWG tinned or untinned copper strands applied as a wrap or braid, or a wrap of aluminum faced polyester tape with a parallel, uninsulated drain wire.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or in the Internal Wiring of Appliances at temperatures not exceeding 105 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024