Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 26 AWG - 20 AWG solid or stranded round, bare, tinned or silver-coated, having a minimum 40 per cent conductivity. |
|
Insulation | Extruded FRPE, 15 mils minimum average thickness, 14 mils minimum thickness at any point |
|
Assembly | Over the conductor shall be applied a spiral wrap of flame-retardant polyethylene thread nominal 25 mils in diameter, approximately 3/8 in. between turns. This assembly shall be enclosed with a flame-retardant polyethylene tube having a nominal 15 mil wall thickness |
|
Covering | An extruded nylon covering, 3 mils nominal thickness, 2 mils minimum at any point thickness to be applied over the tube |
|
Shield | A shield over the nylon covering of the tube shall consist of a bare or tinned copper braid or a wrap of aluminum faced mylar tape with a parallel uninsulated drain wire. |
|
Braid | Optional. |
|
Jacket | Extruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring |
|