APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1301 Issued:1962-05-24
Revised:2012-06-07
Style 1301 Multiconductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor26-16 AWG. Solid or stranded copper wire with 30 AWG or smaller strands, tinned or bare.
InsulationExtruded PE, 45 mils min average, 40 mils minimum at any point.
CoveringOptional. Lacquered textile braid applied between the insulation and the shield.
ShieldOptional.
JacketExtruded PVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024