Rating | 80 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 26-16 AWG. Solid or stranded copper wire with 30 AWG or smaller strands, tinned or bare. |
|
Insulation | Extruded PE, 45 mils min average, 40 mils minimum at any point. |
|
Covering | Optional. Lacquered textile braid applied between the insulation and the shield. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|