APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1309 Issued:2000-09-24
Revised:2011-09-23
Style 1309 Single Conductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded.
InsulationExtruded PE, 30 mils min average thickness, 26 mils minimum at any point.
ShieldShielding over insulation shall consist of No. 36-30 AWG tinned or untinned copper strands applied as a wrap or braid, or a wrap of aluminum faced Polyester tape with a parallel, uninsulated drain wire.
JacketExtruded PVC, 45 mils min average, 36 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick Up and Volume Control; or in the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.