APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1311 Issued:1962-09-28
Revised:2008-05-27
Style 1311 Insulated Wire.

Rating80 deg C, 600 Vac, Horizontal flame, Oil Res 60 or 80 deg C (optional), Moisture Res 60 deg C
Conductor18 AWG - 10 AWG consisting of 30 AWG or smaller stranded, tinned or bare copper.
InsulationPVC, 60 mils min average, 54 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerating Equipment or Air Conditioning Equipment at temperatures not exceeding 80 deg C; or where exposed to oil at temperatures not exceeding (60 deg C or 80 deg C) whichever is applicable; Moisture Resistant, 60 deg C.
 