APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1323 Issued:1962-12-26
Revised:2012-02-01
Style 1323 Single conductor with extruded insulation

Rating60, 80 deg C, 600 Vac, Horizontal flame, Moisture Res 60 deg C, (optional) Oil Res 60 or 80 deg C
Conductor14 AWG - 10 AWG consisting of 30 AWG or smaller stranded
InsulationExtruded PVC, 80 mils min average, 72 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerating Equipment or Room Air Conditioners or Room Cooler Units or Internal Wiring of Remote Outdoor condensing Units for Domestic Cooling Systems where exposed to temperatures not exceeding 80 deg C, or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C) whichever is applicable. Moisture Resistant 60 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024