APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1325 Issued:1963-01-11
Revised:2012-11-30
Style 1325 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG solid or stranded.
InsulationExtruded PE, 31 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldA black colored conductive thermoplastic material 7 mils nominal, 6 mils minimum wall, in conjunction with a 26, 24, or 22 AWG stranded or solid, tinned or bare copper bonding conductor.
JacketExtruded PVC, 31 mils minimum average thickness, 24 mils minimum thickness at any point. The color of the jacket shall be other than black.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control; or In the Internal Wiring of Appliances at temperatures not exceeding 80 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024