APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1330 Issued:1963-02-04
Revised:2010-02-12
Style 1330 Insulated Wire.

Rating200 deg C, 600 Vac, Horizontal flame, Optional Oil Resistant 80 deg C, Optional Gasoline Resistant.
Conductor30 AWG - 4/0 AWG, solid or stranded.
InsulationFEP.
Conductor sizeMinimum averageMinimum at any point
30-10 AWG20 mils18 mils
9-2 AWG30 mils27 mils
1-4/0 AWG45 mils40 mils
CoveringOptional, FEP, 10 mils or heavier or glass braid 7 mils or heavier.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances. In addition, the tag may also indicate the following: Suitable for immersion in gasoline; gasoline vapor; and 80 deg. C in oil.
 
UL and the UL Logo are trademarks of UL LLC © 2024