APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1348 Issued:1963-10-16
Revised:2012-02-29
Style 1348 Single-conductor cable using extruded insulation and non-integral jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG, stranded round.
InsulationExtruded PE, 16 mils minimum average, 13 mils minimum at any point.
ShieldA black colored conductive thermoplastic material 7 mils minimum average, 6 mils minimum at any point, wall, in conjunction with a 26, 24 or 22 AWG, stranded or solid, tinned or bare copper bonding conductor.
JacketExtruded PVC, 16 mils minimum average, 13 mils minimum at any point. The color of the jacket shall be other than black.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn electronic equipment where exposed to temperature not exceeding 60 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024