APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1350 Issued:1963-10-22
Revised:2012-03-22
Style 1350 Single-conductor cable using non-integral jacket.

Rating80 deg C, 600 Vac, Horizontal flame, Optional-60 deg C Oil.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE, 28 mils min average, 23 mils minimum at any point.
JacketExtruded PVC, 20 mils min average, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024