APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1356 Issued:1964-04-23
Revised:2011-07-28
Style 1356 Single Conductor with Extruded Insulation and Non-Integral Jacket

Rating60 deg C, 300 Vac, Horizontal flame.
ConductorNo. 27 AWG, 7/0.0056 mils diameter strands.
InsulationPE, 45 mils minimum average thickness, 40 mils minimum thickness at any point.
ShieldIn accordance with Standard
JacketPVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Computers.

UL and the UL Logo are trademarks of UL LLC © 2024