|
Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 16 AWG, solid or stranded. |
|
Insulation | Extruded FRPE or extruded PE, 23 mils minimum average thickness, 20 mils minimum thickness at any point. |
|
Covering | Optional. Extruded PVC, extruded nylon (polyamide), or extruded Polyester, 2 mils minimum thickness, or lacquered braid. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
Shield | Optional. |
|
Jacket | Optional. Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|