APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1365 Issued:1964-10-22
Revised:2011-09-14
Style 1365 Single Conductor Cable with Extruded Insulation and Extruded Non-Integral Jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded FRPE or extruded PE, 23 mils minimum average thickness, 20 mils minimum thickness at any point.
CoveringOptional. Extruded PVC, extruded nylon (polyamide), or extruded Polyester, 2 mils minimum thickness, or lacquered braid.
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
ShieldOptional.
JacketOptional. Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024