Rating | 60, 80 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 36 AWG minimum, solid or stranded. |
|
Insulation | Extruded PE, extruded foamed PE, extruded XLPE, extruded foamed XLPE, extruded FRPE, extruded foamed FRPE, extruded XLFRPE, extruded foamed XLFRPE, extruded FEP, extruded foamed FEP, extruded XLFEP, extruded foamed XLFEP, extruded PFA, extruded foamed PFA, extruded XLPFA, extruded foamed XLPFA, extruded PTFE, extruded foamed PTFE, extruded XLPTFE, extruded foamed XLPTFE, extruded PP, extruded foamed PP, extruded XLPP or extruded foamed XLPP, wall thickness may range from minimum 0.007 to 0.150 inches maximum. |
|
Shield | Optional. |
|
Inner Covering | Optional. Extruded PVC, extruded PE, extruded FRPE, extruded PFA, extruded FEP, extruded PTFE, extruded Nylon (polyamide), extruded ETFE, extruded polyester or extruded TPU, approx 0.002 inches thick, or non-extruded lacquered braid, or spiral wrap of minimum 0.0006 inches thick non-extruded PETP tape applied with approx 50 percent overlap. |
|
Shield | Optional. |
|
Outer Covering | Optional. Extruded PVC, extruded PE, extruded FRPE, extruded FEP, extruded PFA, extruded PTFE, extruded Nylon (polyamide), extruded ETFE, extruded polyester or extruded TPU, approx 0.002 inches thick, or spiral wrap of minimum 0.0006 inches thick non-extruded PETP tape applied with approx 50 percent overlap, or non-extruded lacquered braid. |
|
Shield | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of Class 2 circuits in appliances, electronic equipment and electronic business machines. |
|