APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1376 Issued:1965-03-04
Revised:2012-04-19
Style 1376 Single-conductor cable using non-integral jacket.

Rating90 deg C, 250 Vac, FT2 flame, 60 deg C Wet.
ConductorSize varies - dependent upon wattage demand, solid or stranded.
InsulationExtruded PVC, 30 mils min average. R/C QMTT2 compounds suitable for at least Type TW, or see Facing page.
ShieldCopper braid consisting of bare copper. Combination of strand size and number of strands such that braid is equivalent to 18 AWG.
JacketExtruded PVC, 20 mils min average, 16 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
Use"Thermoplastic Insulated Resistance Wire for Heating Cable Units" The conductor alloy designation shall be included in Ohms per foot rating (optional marking).

UL and the UL Logo are trademarks of UL LLC © 2024