APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1379 Issued:1965-03-19
Revised:2012-07-24
Style 1379 Single conductor with extruded insulation and non integral jacket

Rating60, 80 deg C, 150 Vac, Horizontal flame.
Conductor29 AWG - 20 AWG Copper, copper-clad steel, copper alloy, bare, tinned or silver-coated, having a minimum of 40 percent conductivity.
InsulationFRPE, 15 mils min average, 13 mils minimum at any point.
AssemblyOver the conductor shall be applied a spiral wrap of PE or FRPE thread nominally 15 mils in dia. approximately 1/2 in. between turns. This assembly shall be enclosed with a flame-retardant polyethylene tube having an approximately 15 mil wall.
ShieldOptional.
JacketExtruded PVC, 9 mils min average, 8 mils min.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring

UL and the UL Logo are trademarks of UL LLC © 2024