APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1390 Issued:1965-06-18
Revised:2012-03-02
Style 1390 Single or multiple conductor with extruded insulation

Rating90 deg C, 600 Vac, Horizontal flame, Oil Res 60 deg C or 80 deg C (optional), Moisture Res 60 deg C
Conductor18 AWG - 2 AWG solid or stranded round, tinned or bare copper.
InsulationPVC, 60 mils min average, 54 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerating Equipment or Room Air Conditioners or Room Cooler Units where exposed to temperatures not exceeding 90 deg C; or Internal Wiring of Electric Refrigerating Equipment or Room Air Conditioners or Room Cooler Units or Internal Wiring of Remote Outdoor Condensing Units for Domestic Cooling Systems where exposed to temperatures not exceeding 90 deg C, or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Moisture Resistant, 60 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024