APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1392 Issued:1965-06-18
Revised:2011-07-28
Style 1392 Single conductor with extruded insulation

Rating90 deg C, 600 Vac, Horizontal flame, 60 deg C Wet. Optional - 60 or 80 deg C Oil.
Conductor26 AWG - 9 AWG solid or stranded.
InsulationExtruded PVC, 30 mils min average, 27 mils minimum at any point. Recognized (QMTT2) Compounds also suitable for use at 90 C in air or 60 C or 80 C in oil.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electric Refrigerating Equipment or Room Air Conditioners or Room Cooler Units or Internal Wiring of Refrigerating Equipment or Room Air Conditioners or Room Cooler Units or Internal Wiring of Remote Outdoor Condensing Units for Domestic Cooling Systems, or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Moisture Resistant 60 deg C.

UL and the UL Logo are trademarks of UL LLC © 2024