APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1405 Issued:1966-03-04
Revised:2011-09-23
Style 1405 Single Conductor Cable with Extruded Non-Integral Jacket

Rating90 deg C, 600 Vac, Horizontal flame, Oil Resistant 60 deg C (optional), Moisture Resistant 60 deg C
Conductor1 AWG - 4/0 AWG solid or stranded round, tinned or bare copper.
InsulationClass 43 and TW grade PVC. PVC, 78 mils min average, 70 mils minimum at any point.
JacketPolyamide, 10 mile minimum average, 8 mils minimum at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances; or internal wiring of appliances where exposed to oil at a temperature not exceeding 60¢XC. Moisture rating 60 deg.C.