APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1415 Issued:1966-03-28
Revised:2012-03-09
Style 1415 Single Conductor with Extruded Insulation

Rating90 deg C, 600 Vac, Horizontal flame, Moisture Resistant 60 deg C.
ConductorResistance Wire. Size varies dependent upon wattage demand.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
ShieldCopper braid consisting of bare copper, combination of strand size and number of strands such that braid is equivalent to 18 AWG.
CoveringExtruded nylon in 3 mil minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. Ohms per foot rating (optional). The conductor alloy designation shall be included.
UseThermoplastic Insulated Resistance Wire for Heating Cable Units

UL and the UL Logo are trademarks of UL LLC © 2024