APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1435 Issued:1967-07-14
Revised:2014-07-02
Style 1435 Single conductor with extruded insulation and jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 10 AWG, solid or stranded.
InsulationSolid PE, Foam PE or FRPE
Conductor size(AWG)Minimum average thickness(mils)Minimum thickness at any point(mils)
30-161513
15-102018
Barrier TapeOptional, polyester tape
ShieldOptional.
CoveringOptional. A textile braid, nylon jacket (2 mil minimum thickness), or minimum 8 mils of semi-rigid or regular PVC may be applied between the insulation and shield
JacketExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024