| Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor | 27 AWG - 16 AWG, solid or stranded. |
|
| Insulation | Extruded FRPE or PE, 30 mils minimum average thickness, 27 mils minimum thickness at any point. |
|
| Covering | Optional. Extruded Nylon, PE, FRPE or PVC, 2 mils minimum thickness, or textile braid. |
|
| Shield | Optional. |
|
| Jacket | Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring. |
|