APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1441 Issued:1967-10-18
Revised:2012-04-27
Style 1441 Single Conductor with Exruded Insulation.

Rating75 deg C, 600 Vac, Horizontal flame.
Conductor18 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
CoveringExtruded nylon in 4-mil minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. Surface marking: "Gasoline and Oil resistant 60 deg C" at intervals not greater than 6 in.
UseInternal wiring of appliances