APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1452 Issued:1968-06-20
Revised:2011-07-27
Style 1452 Single Conductor Cable with Non-Integral Jacket.

Rating90 deg C, 1000 Vac, Horizontal flame, 60 or 80 deg C Oil, Gasoline. Optional - Oil Resistant, Gasoline Resistant.
Conductor26 AWG - 12 AWG, solid or stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
CoveringExtruded nylon (polyamide), 4 mils minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances. Tags may also indicate the following: "3500 V peak for electronic use only." In addition, the tag may also indicate the following: Suitable for a) Immersion in gasoline. b) Exposure to gasoline vapor. c) Immersion in oil at 60 deg C or 80 deg C (whichever is applicable).