APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1460 Issued:1968-11-07
Revised:2012-01-29
Style 1460 Single conductor cable with extruded insulation and jacket.

Rating80 deg C, 150 Vac (Jacket), Horizontal Flame.
Conductor29 AWG - 20 AWG, solid or stranded round copper-clad steel, bare, tinned or silver-coated, having a minimum 40 per cent conductivity .
InsulationExtruded FRPP, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyOver the conductor shall be applied a spiral wrap of FRPP thread nominally 15 mils in diameter, approximately 0.5 in. between turns. This assembly shall be enclosed with a FRPP tube having an approximately 15 mil wall.
ShieldA shield over the tube shall consist of a bare or tinned copper braid. A drain wire may be applied under the shield
JacketExtruded PVC, 9 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024