Rating | 80 deg C, 300 Vac (Jacket), Horizontal flame. |
|
Conductor | 26 AWG - 20 AWG solid or stranded round, copper-clad steel, bare, tinned or silver- coated, having a minimum 40 per cent conductivity. |
|
Insulation | FRPP. Over the conductor shall be applied a spiral wrap of FRPP thread nominally 25 mils in diameter, approximately 0.5 in. between turns. This assembly shall be enclosed with a FRPP tube having an approximately 20 mil wall. |
|
Shield | A shield over the tube shall consist of a bare or tinned copper braid. A drain wire may be applied under the shield. |
|
Jacket | PVC, 18 mils min average, 14 mils minimum at any point. (outer jacket) |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | In electronic equipment where exposed to a temperature not exceeding 80 deg C and where the Jacket is exposed to a maximum operating potential of 300 Volts. |
|