APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1461 Issued:1968-10-07
Revised:2012-04-20
Style 1461 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac (Jacket), Horizontal flame.
Conductor26 AWG - 20 AWG solid or stranded round, copper-clad steel, bare, tinned or silver- coated, having a minimum 40 per cent conductivity.
InsulationFRPP. Over the conductor shall be applied a spiral wrap of FRPP thread nominally 25 mils in diameter, approximately 0.5 in. between turns. This assembly shall be enclosed with a FRPP tube having an approximately 20 mil wall.
ShieldA shield over the tube shall consist of a bare or tinned copper braid. A drain wire may be applied under the shield.
JacketPVC, 18 mils min average, 14 mils minimum at any point. (outer jacket)
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn electronic equipment where exposed to a temperature not exceeding 80 deg C and where the Jacket is exposed to a maximum operating potential of 300 Volts.